| Number of credits available | Minimum standards |
|---|---|
| 1 | No |
To reduce the need to commute to work by providing residents with the necessary space and services to be able to work from home.
The following is required to demonstrate compliance:
| 1 | A home office has been provided within each dwelling with adequate space and services, as follows: |
| 1.a | For dwellings with one or two bedrooms or studio homes, space is provided in the living room, one of the bedrooms or any other suitable area in the home such as a large hall or dining area |
| 1.b | For dwellings with three or more bedrooms, sufficient working space is provided within a room other than the kitchen, living room or master bedroom or bathroom |
| 1.c | In all cases, the room is large enough not to prevent the intended use of that room, i.e. a home office set up in the main bedroom does not compromise the ability for a double bed and other necessary furnishing to be contained within that room. |
| 2 | Sufficient services must include as a minimum: |
| 2.a | Two double power sockets |
| 2.b | Two telephone points (or double telephone point) or one telephone point where the dwelling is connected to a cable or broadband service available at the address |
| 2.c | Adequate daylight, the room chosen to be the nominated home office must have a compliant average daylight factor, see Hea 01 Visual comfort: Table 10 |
| 2.d | Adequate ventilation, either through an openable window or alternative ventilation such as passive stack, mechanical ventilation, etc. |
None.
| Ref | Terms | Description |
|---|---|---|
| Shell and core (non-residential and residential institutions only) | ||
CN1 | Applicable assessment criteria | Both options: This issue is not applicable to non-residential and residential institutions. Refer to Appendix D – Shell and core project assessments for a more detailed description of the shell and core assessment options. |
Residential - Partially fitted and fully fitted | ||
CN2 | Applicable assessment criteria - Single and multiple dwellings | Partially fitted: This issue is not applicable. Fully fitted: All criteria relevant to the building type and function apply.Refer to Appendix E – Applicability of BREEAM New Construction to single and multiple dwellings, partially and fully fitted for a more detailed description of residential assessment options. |
| General | ||
CN3 | Sufficient space | This is defined as the minimum size (1.8m wall length) to:
The 1.8m wall size requirement can, in some circumstances, be altered if drawings can prove that a desk can be fitted in any other type of arrangement, i.e. alcove or similar, fulfilling all the above criteria. |
CN3.1 | Adequate ventilation | Rooms intended to be used as a home office must meet the requirements in Hea 02 Indoor air quality |
None.
| Criteria. | Interim design stage | Final post-construction stage |
|---|---|---|
| All | Scaled drawings or a copy of the specification. | As-built drawings or assessor’s site inspection report confirming the details required at the design stage. |
None.
None.